Falsely normal value in fluorometric transferase screening of galactosemic blood. A cautionary note.
Am J Clin Pathol. 1981 Dec; 76(6):841-2.AJ

Abstract

A blood sample from a galactosemic infant gave a normal result with the fluorescent screening test for galactose-1-phosphate uridyl transferase. The generation of fluorescence from this sample was found to be property of the plasma; the erythrocytes manifested no galactose-1-phosphate uridyl transferase activity. The plasma was found to contain a high level of isocitrate dehydrogenase, presumably a result of the infant's liver disease, and of isocitrate, presumably derived from citrate in the anticoagulant solution by action of aconitase derived from leukocytes which lysed during shipment. The oxidation of the isocitrate by the dehydrogenase apparently resulted in reduction of NADP to NADPH. False negative results have not been reported previously using the fluorescent transferase assay. They can be avoided in the future by using EDTA rather than citrate as an anticoagulant, particularly if blood samples are to be shipped at ambient temperature.

Authors

No affiliation info availableNo affiliation info available

Pub Type(s)

Case Reports
Journal Article
Research Support, U.S. Gov't, P.H.S.

Language

eng

PubMed ID

6274187

Citation

Beutler, E, and T Gelbart. "Falsely Normal Value in Fluorometric Transferase Screening of Galactosemic Blood. a Cautionary Note." American Journal of Clinical Pathology, vol. 76, no. 6, 1981, pp. 841-2.
Beutler E, Gelbart T. Falsely normal value in fluorometric transferase screening of galactosemic blood. A cautionary note. Am J Clin Pathol. 1981;76(6):841-2.
Beutler, E., & Gelbart, T. (1981). Falsely normal value in fluorometric transferase screening of galactosemic blood. A cautionary note. American Journal of Clinical Pathology, 76(6), 841-2.
Beutler E, Gelbart T. Falsely Normal Value in Fluorometric Transferase Screening of Galactosemic Blood. a Cautionary Note. Am J Clin Pathol. 1981;76(6):841-2. PubMed PMID: 6274187.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Falsely normal value in fluorometric transferase screening of galactosemic blood. A cautionary note. AU - Beutler,E, AU - Gelbart,T, PY - 1981/12/1/pubmed PY - 1981/12/1/medline PY - 1981/12/1/entrez SP - 841 EP - 2 JF - American journal of clinical pathology JO - Am J Clin Pathol VL - 76 IS - 6 N2 - A blood sample from a galactosemic infant gave a normal result with the fluorescent screening test for galactose-1-phosphate uridyl transferase. The generation of fluorescence from this sample was found to be property of the plasma; the erythrocytes manifested no galactose-1-phosphate uridyl transferase activity. The plasma was found to contain a high level of isocitrate dehydrogenase, presumably a result of the infant's liver disease, and of isocitrate, presumably derived from citrate in the anticoagulant solution by action of aconitase derived from leukocytes which lysed during shipment. The oxidation of the isocitrate by the dehydrogenase apparently resulted in reduction of NADP to NADPH. False negative results have not been reported previously using the fluorescent transferase assay. They can be avoided in the future by using EDTA rather than citrate as an anticoagulant, particularly if blood samples are to be shipped at ambient temperature. SN - 0002-9173 UR - https://www.unboundmedicine.com/medline/citation/6274187/Falsely_normal_value_in_fluorometric_transferase_screening_of_galactosemic_blood__A_cautionary_note_ L2 - https://academic.oup.com/ajcp/article-lookup/doi/10.1093/ajcp/76.6.841 DB - PRIME DP - Unbound Medicine ER -