Systematic error between erythrocyte protoporphyrin in proficiency test samples and patients' samples as measured with two hematofluorometers.
Clin Chem. 1982 Dec; 28(12):2421-2.CC

Abstract

Hematofluorometers manufactured by two different companies (Aviv Biomedical and Environmental Science Associates) performed satisfactorily for protoporphyrin determinations with proficiency test samples but showed about a 30% low bias with actual clinical blood specimens.

Authors

No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Comparative Study
Journal Article

Language

eng

PubMed ID

7139924

Citation

Balamut, R, et al. "Systematic Error Between Erythrocyte Protoporphyrin in Proficiency Test Samples and Patients' Samples as Measured With Two Hematofluorometers." Clinical Chemistry, vol. 28, no. 12, 1982, pp. 2421-2.
Balamut R, Doran D, Giridhar G, et al. Systematic error between erythrocyte protoporphyrin in proficiency test samples and patients' samples as measured with two hematofluorometers. Clin Chem. 1982;28(12):2421-2.
Balamut, R., Doran, D., Giridhar, G., Mitchell, D., & Soule, S. (1982). Systematic error between erythrocyte protoporphyrin in proficiency test samples and patients' samples as measured with two hematofluorometers. Clinical Chemistry, 28(12), 2421-2.
Balamut R, et al. Systematic Error Between Erythrocyte Protoporphyrin in Proficiency Test Samples and Patients' Samples as Measured With Two Hematofluorometers. Clin Chem. 1982;28(12):2421-2. PubMed PMID: 7139924.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Systematic error between erythrocyte protoporphyrin in proficiency test samples and patients' samples as measured with two hematofluorometers. AU - Balamut,R, AU - Doran,D, AU - Giridhar,G, AU - Mitchell,D, AU - Soule,S, PY - 1982/12/1/pubmed PY - 1982/12/1/medline PY - 1982/12/1/entrez SP - 2421 EP - 2 JF - Clinical chemistry JO - Clin Chem VL - 28 IS - 12 N2 - Hematofluorometers manufactured by two different companies (Aviv Biomedical and Environmental Science Associates) performed satisfactorily for protoporphyrin determinations with proficiency test samples but showed about a 30% low bias with actual clinical blood specimens. SN - 0009-9147 UR - https://www.unboundmedicine.com/medline/citation/7139924/Systematic_error_between_erythrocyte_protoporphyrin_in_proficiency_test_samples_and_patients'_samples_as_measured_with_two_hematofluorometers_ L2 - https://medlineplus.gov/leadpoisoning.html DB - PRIME DP - Unbound Medicine ER -