The evaluation of a photometer (the Radiometer OSM2) for the determination of haemoglobin concentration and per cent oxyhaemoglobin and carboxyhaemoglobin in blood.J Med Eng Technol. 1981 Nov; 5(6):298-300.JM
Abstract
Haemoglobin concentration and its saturation with oxygen and carbon monoxide were estimated in identical blood samples using an automated two-wavelength photometer (the Radiometer OSM2) and standard methods. The instrument was easy to operate and maintain and, in general, was accurate and repeatable. At carboxyhaemoglobin levels below 1.5%, however, the precision of the instrument was poor.
Links
MeSH
Pub Type(s)
Comparative Study
Journal Article
Language
eng
PubMed ID
7328626
Citation
Saloojee, Y, et al. "The Evaluation of a Photometer (the Radiometer OSM2) for the Determination of Haemoglobin Concentration and Per Cent Oxyhaemoglobin and Carboxyhaemoglobin in Blood." Journal of Medical Engineering & Technology, vol. 5, no. 6, 1981, pp. 298-300.
Saloojee Y, Cole PV, Adams L. The evaluation of a photometer (the Radiometer OSM2) for the determination of haemoglobin concentration and per cent oxyhaemoglobin and carboxyhaemoglobin in blood. J Med Eng Technol. 1981;5(6):298-300.
Saloojee, Y., Cole, P. V., & Adams, L. (1981). The evaluation of a photometer (the Radiometer OSM2) for the determination of haemoglobin concentration and per cent oxyhaemoglobin and carboxyhaemoglobin in blood. Journal of Medical Engineering & Technology, 5(6), 298-300.
Saloojee Y, Cole PV, Adams L. The Evaluation of a Photometer (the Radiometer OSM2) for the Determination of Haemoglobin Concentration and Per Cent Oxyhaemoglobin and Carboxyhaemoglobin in Blood. J Med Eng Technol. 1981;5(6):298-300. PubMed PMID: 7328626.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - The evaluation of a photometer (the Radiometer OSM2) for the determination of haemoglobin concentration and per cent oxyhaemoglobin and carboxyhaemoglobin in blood.
AU - Saloojee,Y,
AU - Cole,P V,
AU - Adams,L,
PY - 1981/11/1/pubmed
PY - 1981/11/1/medline
PY - 1981/11/1/entrez
SP - 298
EP - 300
JF - Journal of medical engineering & technology
JO - J Med Eng Technol
VL - 5
IS - 6
N2 - Haemoglobin concentration and its saturation with oxygen and carbon monoxide were estimated in identical blood samples using an automated two-wavelength photometer (the Radiometer OSM2) and standard methods. The instrument was easy to operate and maintain and, in general, was accurate and repeatable. At carboxyhaemoglobin levels below 1.5%, however, the precision of the instrument was poor.
SN - 0309-1902
UR - https://www.unboundmedicine.com/medline/citation/7328626/The_evaluation_of_a_photometer__the_Radiometer_OSM2__for_the_determination_of_haemoglobin_concentration_and_per_cent_oxyhaemoglobin_and_carboxyhaemoglobin_in_blood_
L2 - https://www.tandfonline.com/doi/full/10.3109/03091908109009365
DB - PRIME
DP - Unbound Medicine
ER -