Tags

Type your tag names separated by a space and hit enter

The evaluation of a photometer (the Radiometer OSM2) for the determination of haemoglobin concentration and per cent oxyhaemoglobin and carboxyhaemoglobin in blood.
J Med Eng Technol. 1981 Nov; 5(6):298-300.JM

Abstract

Haemoglobin concentration and its saturation with oxygen and carbon monoxide were estimated in identical blood samples using an automated two-wavelength photometer (the Radiometer OSM2) and standard methods. The instrument was easy to operate and maintain and, in general, was accurate and repeatable. At carboxyhaemoglobin levels below 1.5%, however, the precision of the instrument was poor.

Authors

No affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Comparative Study
Journal Article

Language

eng

PubMed ID

7328626

Citation

Saloojee, Y, et al. "The Evaluation of a Photometer (the Radiometer OSM2) for the Determination of Haemoglobin Concentration and Per Cent Oxyhaemoglobin and Carboxyhaemoglobin in Blood." Journal of Medical Engineering & Technology, vol. 5, no. 6, 1981, pp. 298-300.
Saloojee Y, Cole PV, Adams L. The evaluation of a photometer (the Radiometer OSM2) for the determination of haemoglobin concentration and per cent oxyhaemoglobin and carboxyhaemoglobin in blood. J Med Eng Technol. 1981;5(6):298-300.
Saloojee, Y., Cole, P. V., & Adams, L. (1981). The evaluation of a photometer (the Radiometer OSM2) for the determination of haemoglobin concentration and per cent oxyhaemoglobin and carboxyhaemoglobin in blood. Journal of Medical Engineering & Technology, 5(6), 298-300.
Saloojee Y, Cole PV, Adams L. The Evaluation of a Photometer (the Radiometer OSM2) for the Determination of Haemoglobin Concentration and Per Cent Oxyhaemoglobin and Carboxyhaemoglobin in Blood. J Med Eng Technol. 1981;5(6):298-300. PubMed PMID: 7328626.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - The evaluation of a photometer (the Radiometer OSM2) for the determination of haemoglobin concentration and per cent oxyhaemoglobin and carboxyhaemoglobin in blood. AU - Saloojee,Y, AU - Cole,P V, AU - Adams,L, PY - 1981/11/1/pubmed PY - 1981/11/1/medline PY - 1981/11/1/entrez SP - 298 EP - 300 JF - Journal of medical engineering & technology JO - J Med Eng Technol VL - 5 IS - 6 N2 - Haemoglobin concentration and its saturation with oxygen and carbon monoxide were estimated in identical blood samples using an automated two-wavelength photometer (the Radiometer OSM2) and standard methods. The instrument was easy to operate and maintain and, in general, was accurate and repeatable. At carboxyhaemoglobin levels below 1.5%, however, the precision of the instrument was poor. SN - 0309-1902 UR - https://www.unboundmedicine.com/medline/citation/7328626/The_evaluation_of_a_photometer__the_Radiometer_OSM2__for_the_determination_of_haemoglobin_concentration_and_per_cent_oxyhaemoglobin_and_carboxyhaemoglobin_in_blood_ L2 - https://www.tandfonline.com/doi/full/10.3109/03091908109009365 DB - PRIME DP - Unbound Medicine ER -