Tags

Type your tag names separated by a space and hit enter

Assessment of cartilage volume in the femorotibial joint with magnetic resonance imaging and 3D computer reconstruction.
J Rheumatol. 1994 Dec; 21(12):2307-21.JR

Abstract

OBJECTIVE

Our goal was the development of an accurate and objective technique to depict and quantitate articular cartilage using magnetic resonance imaging (MRI) and 3D data processing.

METHODS

A method of 3D image analysis has been developed that provides a noninvasive technique of measuring cartilage volume from standard diagnostic MR images.

RESULTS

Using a computer workstation, cartilage from Fast Field Echo (FFE) MR images was reconstructed into 3 dimensions (3D). The accuracy and reproducibility of both thickness and volume measurements obtained from the existing computer software was tested using calibration test objects. We describe the sources of error we encountered when attempting to quantitate cartilage using the existing computer software, the methods developed to reduce these errors, and a preliminary cartilage volume study using healthy human volunteers.

CONCLUSION

We have identified errors involved in attempting cartilage volume estimations using the existing 3D computer software and have developed a data processing technique that minimizes these errors. With these objective data processing techniques we have improved the reproducibility of the technique to +/- 10-15% error. This modified technique provides a promising new method for viewing and quantifying cartilage volume from standard diagnostic MR images.

Authors+Show Affiliations

Eye Research Institute of Canada, Toronto Hospital, ON.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

7699634

Citation

Pilch, L, et al. "Assessment of Cartilage Volume in the Femorotibial Joint With Magnetic Resonance Imaging and 3D Computer Reconstruction." The Journal of Rheumatology, vol. 21, no. 12, 1994, pp. 2307-21.
Pilch L, Stewart C, Gordon D, et al. Assessment of cartilage volume in the femorotibial joint with magnetic resonance imaging and 3D computer reconstruction. J Rheumatol. 1994;21(12):2307-21.
Pilch, L., Stewart, C., Gordon, D., Inman, R., Parsons, K., Pataki, I., & Stevens, J. (1994). Assessment of cartilage volume in the femorotibial joint with magnetic resonance imaging and 3D computer reconstruction. The Journal of Rheumatology, 21(12), 2307-21.
Pilch L, et al. Assessment of Cartilage Volume in the Femorotibial Joint With Magnetic Resonance Imaging and 3D Computer Reconstruction. J Rheumatol. 1994;21(12):2307-21. PubMed PMID: 7699634.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Assessment of cartilage volume in the femorotibial joint with magnetic resonance imaging and 3D computer reconstruction. AU - Pilch,L, AU - Stewart,C, AU - Gordon,D, AU - Inman,R, AU - Parsons,K, AU - Pataki,I, AU - Stevens,J, PY - 1994/12/1/pubmed PY - 1994/12/1/medline PY - 1994/12/1/entrez SP - 2307 EP - 21 JF - The Journal of rheumatology JO - J Rheumatol VL - 21 IS - 12 N2 - OBJECTIVE: Our goal was the development of an accurate and objective technique to depict and quantitate articular cartilage using magnetic resonance imaging (MRI) and 3D data processing. METHODS: A method of 3D image analysis has been developed that provides a noninvasive technique of measuring cartilage volume from standard diagnostic MR images. RESULTS: Using a computer workstation, cartilage from Fast Field Echo (FFE) MR images was reconstructed into 3 dimensions (3D). The accuracy and reproducibility of both thickness and volume measurements obtained from the existing computer software was tested using calibration test objects. We describe the sources of error we encountered when attempting to quantitate cartilage using the existing computer software, the methods developed to reduce these errors, and a preliminary cartilage volume study using healthy human volunteers. CONCLUSION: We have identified errors involved in attempting cartilage volume estimations using the existing 3D computer software and have developed a data processing technique that minimizes these errors. With these objective data processing techniques we have improved the reproducibility of the technique to +/- 10-15% error. This modified technique provides a promising new method for viewing and quantifying cartilage volume from standard diagnostic MR images. SN - 0315-162X UR - https://www.unboundmedicine.com/medline/citation/7699634/Assessment_of_cartilage_volume_in_the_femorotibial_joint_with_magnetic_resonance_imaging_and_3D_computer_reconstruction_ L2 - https://medlineplus.gov/mriscans.html DB - PRIME DP - Unbound Medicine ER -