Transcutaneous and end-tidal carbon dioxide pressures should be measured during pediatric polysomnography.
Am Rev Respir Dis. 1993 Dec; 148(6 Pt 1):1599-604.AR

Abstract

Pediatric obstructive sleep apnea (OSAS) is characterized by partial airway obstruction, alveolar hypoventilation, and elevated arterial CO2 (PaCO2). Thus, a reliable, practical method of estimating CO2 is needed for pediatric polysomnography. Therefore, we measured both transcutaneous CO2 (PtcCO2) and end-tidal CO2 (PETCO2) in 15 pediatric polysomnographic evaluations. Sleep state, the highest PtcCO2, and the highest PETCO2 were recorded for 5,159 thirty-second epochs. Although PtcCO2 and PETCO2 were available for 78.5 and 73.0% of epochs, respectively, at least one estimator was available for 92% of the epochs. One infant who would not tolerate a nasal sampling catheter had no PETCO2 data. For 13 of 14 studies there was a relatively constant difference between PtcCO2 and PETCO2. The difference between PtcCO2 and PETCO2 was within 4 mm Hg in 63.9% of 3,072 epochs. Across 14 studies, mean PtcCO2 exceeded mean PETCO2 by 2.8 +/- 3.0 mm Hg, and it was within 4 mm Hg in 10 studies. In three subjects, PETCO2 was intermittently or consistently less than PtcCO2 because of tachypnea, increased physiologic dead space, or severe partial airway obstruction; in one subject PtcCO2 exceeded PETCO2 for undetermined reasons during one electrode application. The results of this study indicate that PtcCO2, as well as PETCO2, should be measured during pediatric polysomnography. By utilizing both PtcCO2 and PETCO2 there was a 70% reduction in the number of epochs that could not be assessed for hypoventilation. For an individual subject or electrode application there was a constant, and usually close, relationship, between PtcCO2 and PETCO2.(

ABSTRACT

TRUNCATED AT 250 WORDS)

Authors+Show Affiliations

Department of Pediatrics, McGill University, Montreal Children's Hospital, Quebec, Canada.No affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

8256908

Citation

Morielli, A, et al. "Transcutaneous and End-tidal Carbon Dioxide Pressures Should Be Measured During Pediatric Polysomnography." The American Review of Respiratory Disease, vol. 148, no. 6 Pt 1, 1993, pp. 1599-604.
Morielli A, Desjardins D, Brouillette RT. Transcutaneous and end-tidal carbon dioxide pressures should be measured during pediatric polysomnography. Am Rev Respir Dis. 1993;148(6 Pt 1):1599-604.
Morielli, A., Desjardins, D., & Brouillette, R. T. (1993). Transcutaneous and end-tidal carbon dioxide pressures should be measured during pediatric polysomnography. The American Review of Respiratory Disease, 148(6 Pt 1), 1599-604.
Morielli A, Desjardins D, Brouillette RT. Transcutaneous and End-tidal Carbon Dioxide Pressures Should Be Measured During Pediatric Polysomnography. Am Rev Respir Dis. 1993;148(6 Pt 1):1599-604. PubMed PMID: 8256908.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Transcutaneous and end-tidal carbon dioxide pressures should be measured during pediatric polysomnography. AU - Morielli,A, AU - Desjardins,D, AU - Brouillette,R T, PY - 1993/12/1/pubmed PY - 1993/12/1/medline PY - 1993/12/1/entrez SP - 1599 EP - 604 JF - The American review of respiratory disease JO - Am Rev Respir Dis VL - 148 IS - 6 Pt 1 N2 - Pediatric obstructive sleep apnea (OSAS) is characterized by partial airway obstruction, alveolar hypoventilation, and elevated arterial CO2 (PaCO2). Thus, a reliable, practical method of estimating CO2 is needed for pediatric polysomnography. Therefore, we measured both transcutaneous CO2 (PtcCO2) and end-tidal CO2 (PETCO2) in 15 pediatric polysomnographic evaluations. Sleep state, the highest PtcCO2, and the highest PETCO2 were recorded for 5,159 thirty-second epochs. Although PtcCO2 and PETCO2 were available for 78.5 and 73.0% of epochs, respectively, at least one estimator was available for 92% of the epochs. One infant who would not tolerate a nasal sampling catheter had no PETCO2 data. For 13 of 14 studies there was a relatively constant difference between PtcCO2 and PETCO2. The difference between PtcCO2 and PETCO2 was within 4 mm Hg in 63.9% of 3,072 epochs. Across 14 studies, mean PtcCO2 exceeded mean PETCO2 by 2.8 +/- 3.0 mm Hg, and it was within 4 mm Hg in 10 studies. In three subjects, PETCO2 was intermittently or consistently less than PtcCO2 because of tachypnea, increased physiologic dead space, or severe partial airway obstruction; in one subject PtcCO2 exceeded PETCO2 for undetermined reasons during one electrode application. The results of this study indicate that PtcCO2, as well as PETCO2, should be measured during pediatric polysomnography. By utilizing both PtcCO2 and PETCO2 there was a 70% reduction in the number of epochs that could not be assessed for hypoventilation. For an individual subject or electrode application there was a constant, and usually close, relationship, between PtcCO2 and PETCO2.(ABSTRACT TRUNCATED AT 250 WORDS) SN - 0003-0805 UR - https://www.unboundmedicine.com/medline/citation/8256908/Transcutaneous_and_end-tidal_carbon_dioxide_pressures_should_be_measured_during_pediatric_polysomnography. L2 - https://www.atsjournals.org/doi/10.1164/ajrccm/148.6_Pt_1.1599?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub=pubmed DB - PRIME DP - Unbound Medicine ER -