Tags

Type your tag names separated by a space and hit enter

Analysis of stability of human upright posture based upon the measurement of the head sway.
Med Prog Technol. 1993; 19(1):55-60.MP

Abstract

The paper is dealing with the description of a simple and inexpensive technique for recording and measuring of the head sway during upright stance. In particular the recording system and the evaluation of the body sway data are highlighted. The objectives of the head sway signal analysis are the determination of sway components in the side-to-side (lateral) direction and forward-backward (anteroposterior) direction. It is anticipated that it will be possible to extract from the digitized data some information about the transfer characteristic and stability margin of the neuromuscular control system concerned with the maintenance of equilibrium. Additional information of potential clinical significance could be obtained by correlating the measured sway data with electromyographically determined changes in the activity of the main postural muscles. The information obtained is comparable to that gathered by more sophisticated, and more expensive conventional devices. A special feature is the easy portability of the system which permits collection of stabilometric data even in remote locations, while the analysis on which the diagnostic assessment is based can be performed at a later date in a central facility equipped with the necessary instrumentation.

Authors+Show Affiliations

Department of Electrical Engineering, University of Saskatchewan, Saskatoon, Canada.No affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

8302214

Citation

Koncek, V, et al. "Analysis of Stability of Human Upright Posture Based Upon the Measurement of the Head Sway." Medical Progress Through Technology, vol. 19, no. 1, 1993, pp. 55-60.
Koncek V, Pollak VA, Yu AM. Analysis of stability of human upright posture based upon the measurement of the head sway. Med Prog Technol. 1993;19(1):55-60.
Koncek, V., Pollak, V. A., & Yu, A. M. (1993). Analysis of stability of human upright posture based upon the measurement of the head sway. Medical Progress Through Technology, 19(1), 55-60.
Koncek V, Pollak VA, Yu AM. Analysis of Stability of Human Upright Posture Based Upon the Measurement of the Head Sway. Med Prog Technol. 1993;19(1):55-60. PubMed PMID: 8302214.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Analysis of stability of human upright posture based upon the measurement of the head sway. AU - Koncek,V, AU - Pollak,V A, AU - Yu,A M, PY - 1993/1/1/pubmed PY - 1993/1/1/medline PY - 1993/1/1/entrez SP - 55 EP - 60 JF - Medical progress through technology JO - Med Prog Technol VL - 19 IS - 1 N2 - The paper is dealing with the description of a simple and inexpensive technique for recording and measuring of the head sway during upright stance. In particular the recording system and the evaluation of the body sway data are highlighted. The objectives of the head sway signal analysis are the determination of sway components in the side-to-side (lateral) direction and forward-backward (anteroposterior) direction. It is anticipated that it will be possible to extract from the digitized data some information about the transfer characteristic and stability margin of the neuromuscular control system concerned with the maintenance of equilibrium. Additional information of potential clinical significance could be obtained by correlating the measured sway data with electromyographically determined changes in the activity of the main postural muscles. The information obtained is comparable to that gathered by more sophisticated, and more expensive conventional devices. A special feature is the easy portability of the system which permits collection of stabilometric data even in remote locations, while the analysis on which the diagnostic assessment is based can be performed at a later date in a central facility equipped with the necessary instrumentation. SN - 0047-6552 UR - https://www.unboundmedicine.com/medline/citation/8302214/Analysis_of_stability_of_human_upright_posture_based_upon_the_measurement_of_the_head_sway_ L2 - https://medlineplus.gov/guidetogoodposture.html DB - PRIME DP - Unbound Medicine ER -
Try the Free App:
Prime PubMed app for iOS iPhone iPad
Prime PubMed app for Android
Prime PubMed is provided
free to individuals by:
Unbound Medicine.