Citation
Zhu, Y F., et al. "The Study of 2,3,4-trihydroxyacetophenone and 2,4,6-trihydroxyacetophenone as Matrices for DNA Detection in Matrix-assisted Laser Desorption/ionization Time-of-flight Mass Spectrometry." Rapid Communications in Mass Spectrometry : RCM, vol. 10, no. 3, 1996, pp. 383-8.
Zhu YF, Chung CN, Taranenko NI, et al. The study of 2,3,4-trihydroxyacetophenone and 2,4,6-trihydroxyacetophenone as matrices for DNA detection in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Rapid Commun Mass Spectrom. 1996;10(3):383-8.
Zhu, Y. F., Chung, C. N., Taranenko, N. I., Allman, S. L., Martin, S. A., Haff, L., & Chen, C. H. (1996). The study of 2,3,4-trihydroxyacetophenone and 2,4,6-trihydroxyacetophenone as matrices for DNA detection in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Rapid Communications in Mass Spectrometry : RCM, 10(3), 383-8.
Zhu YF, et al. The Study of 2,3,4-trihydroxyacetophenone and 2,4,6-trihydroxyacetophenone as Matrices for DNA Detection in Matrix-assisted Laser Desorption/ionization Time-of-flight Mass Spectrometry. Rapid Commun Mass Spectrom. 1996;10(3):383-8. PubMed PMID: 8949485.
TY - JOUR
T1 - The study of 2,3,4-trihydroxyacetophenone and 2,4,6-trihydroxyacetophenone as matrices for DNA detection in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
AU - Zhu,Y F,
AU - Chung,C N,
AU - Taranenko,N I,
AU - Allman,S L,
AU - Martin,S A,
AU - Haff,L,
AU - Chen,C H,
PY - 1996/1/1/pubmed
PY - 2000/6/20/medline
PY - 1996/1/1/entrez
SP - 383
EP - 8
JF - Rapid communications in mass spectrometry : RCM
JO - Rapid Commun Mass Spectrom
VL - 10
IS - 3
N2 - The matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometric study of DNA detection using 2,3,4-trihydroxyacetophenone, 2,4,6-trihydroxyacetophenone, and their combination has been carried out systematically. The results show that a mixture of 2,4,6-trihydroxyacetophenone, 2,3,4-trihydroxyacetophenone and ammonium citrate with molar ratios of 2:1:1 serves as a good matrix for the detection of DNA, especially for samples containing a small quantity of DNA such as polymerase chain reaction product. The resolution and shot-to-shot reproducibility using this matrix are better than, and the MALDI sensitivity comparable to, that obtained when using 3-hydroxy picotinic acid (3-HPA), PA and ammonium citrate matrix (9:1:1). The mechanism of desorption/ionization using this matrix is discussed.
SN - 0951-4198
UR - https://www.unboundmedicine.com/medline/citation/8949485/The_study_of_234_trihydroxyacetophenone_and_246_trihydroxyacetophenone_as_matrices_for_DNA_detection_in_matrix_assisted_laser_desorption/ionization_time_of_flight_mass_spectrometry_
L2 - https://doi.org/10.1002/(SICI)1097-0231(199602)10:3<383::AID-RCM485>3.0.CO;2-W
DB - PRIME
DP - Unbound Medicine
ER -