Citation
Tomlinson, A J., et al. "Rapid Loading of Large Sample Volumes, Analyte Cleanup, and Modified Moving Boundary Transient Isotachophoresis Conditions for Membrane Preconcentration-capillary Electrophoresis in Small Diameter Capillaries." Electrophoresis, vol. 17, no. 12, 1996, pp. 1801-7.
Tomlinson AJ, Benson LM, Jameson S, et al. Rapid loading of large sample volumes, analyte cleanup, and modified moving boundary transient isotachophoresis conditions for membrane preconcentration-capillary electrophoresis in small diameter capillaries. Electrophoresis. 1996;17(12):1801-7.
Tomlinson, A. J., Benson, L. M., Jameson, S., & Naylor, S. (1996). Rapid loading of large sample volumes, analyte cleanup, and modified moving boundary transient isotachophoresis conditions for membrane preconcentration-capillary electrophoresis in small diameter capillaries. Electrophoresis, 17(12), 1801-7.
Tomlinson AJ, et al. Rapid Loading of Large Sample Volumes, Analyte Cleanup, and Modified Moving Boundary Transient Isotachophoresis Conditions for Membrane Preconcentration-capillary Electrophoresis in Small Diameter Capillaries. Electrophoresis. 1996;17(12):1801-7. PubMed PMID: 9034760.
TY - JOUR
T1 - Rapid loading of large sample volumes, analyte cleanup, and modified moving boundary transient isotachophoresis conditions for membrane preconcentration-capillary electrophoresis in small diameter capillaries.
AU - Tomlinson,A J,
AU - Benson,L M,
AU - Jameson,S,
AU - Naylor,S,
PY - 1996/12/1/pubmed
PY - 1996/12/1/medline
PY - 1996/12/1/entrez
SP - 1801
EP - 7
JF - Electrophoresis
JO - Electrophoresis
VL - 17
IS - 12
N2 - Using a removable membrane preconcentration (mPC) cartridge, large sample volumes can be loaded prior to final assembly of the mPC capillary electrophoresis (CE) capillary. For narrow-bore (< or = 25 microns ID) uncoated mPC-CE capillaries, applied to peptide analysis, efficient moving boundary transient isotachphoresis (tITP) conditions at the onset of electrophoresis are described. The enhancement of mPC-CE-mass spectrometry (MS) technology afforded by rapid sample loading and modified moving boundary tITP conditions are demonstrated by analysis of major histocompatibility complex (MHC) class I peptides that were derived from a Kb precipitation of mouse EL-4 cells. Furthermore, we demonstrate the structural characterization of these immunologically significant molecules by mPC-CE-tandem mass spectrometry (mPC-CE-MS/MS).