An evaluation of serum troponin T and signal-averaged electrocardiography in predicting electrocardiographic abnormalities after blunt chest trauma.
J Trauma. 1997 Aug; 43(2):304-10; discussion 310-2.JT

Abstract

OBJECTIVE

Despite multiple inquiries, there are no available tests to definitively detect blunt myocardial injury. The evaluation of patients with chest wall injuries without other indications for intensive care unit (ICU) admission has ranged from a single emergency department electrocardiogram (ECG) to 72 hours of continuous electrocardiographic monitoring. Recently, signal-averaged ECG and serum cardiac troponin T have demonstrated clinical utility in the evaluation of ischemic heart disease. The purpose of this study is to determine the ability of these diagnostic tests to predict the occurrence of significant electrocardiographic rhythm disturbances for patients with chest wall injuries and no other indication for ICU admission.

METHODS

We prospectively evaluated 71 consecutive adult patients admitted to a regional Level I trauma center with chest wall injuries not requiring ICU admission. We obtained admission signal-averaged ECG, serum troponin T level, standard ECG, and creatine phosphokinase (CPK-MB) level. Patients received continuous electrocardiographic monitoring, follow-up 12-lead electrocardiography, and serial monitoring of troponin and CPK-MB. Echocardiography was performed for patients with abnormal CPK-MB levels. Electrocardiographic events were graded as normal, abnormal but clinically insignificant, or clinically significant. Multiple stepwise logistic regression analysis was used to evaluate predictors for the development of clinically significant electrocardiographic events.

RESULTS

On admission, 17 of 71 patients (23.9%) had normal sinus rhythm; 13 (18.3%) had a clinically significant finding. For 50 patients, follow-up ECG was abnormal; for 26, the findings were clinically significant. Of 17 patients with normal initial ECGs, 7 (41%) developed a clinically significant abnormality. Six patients received intervention for ECG findings. Eleven of 71 patients (16%) had positive troponin T; 5 of 71 (7%) had positive CPK-MB; 15 of 71 (21%) had positive signal-averaged ECG; and 4 of 13 had positive echocardiograms. Initial electrocardiographic abnormalities and a troponin T level > 0.20 microg/L were the only variables found to predict clinically significant electrocardiographic events. Sensitivity and specificity of troponin T in predicting clinically significant abnormalities were 27 and 91%, respectively.

CONCLUSIONS

1. The best predictors for the development of significant electrocardiographic changes are an admission ECG abnormality and an elevated serum troponin T level. 2. Both tests have high specificity with low to moderate sensitivity. 3. Patients with normal ECGs may develop clinically significant events. 4. CPK-MB and echocardiograms continue to be poor predictors of significant electrocardiographic events.

Authors+Show Affiliations

Department of Surgery, Medical Center of Delaware, Wilmington, USA.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

9291377

Citation

Fulda, G J., et al. "An Evaluation of Serum Troponin T and Signal-averaged Electrocardiography in Predicting Electrocardiographic Abnormalities After Blunt Chest Trauma." The Journal of Trauma, vol. 43, no. 2, 1997, pp. 304-10; discussion 310-2.
Fulda GJ, Giberson F, Hailstone D, et al. An evaluation of serum troponin T and signal-averaged electrocardiography in predicting electrocardiographic abnormalities after blunt chest trauma. J Trauma. 1997;43(2):304-10; discussion 310-2.
Fulda, G. J., Giberson, F., Hailstone, D., Law, A., & Stillabower, M. (1997). An evaluation of serum troponin T and signal-averaged electrocardiography in predicting electrocardiographic abnormalities after blunt chest trauma. The Journal of Trauma, 43(2), 304-10; discussion 310-2.
Fulda GJ, et al. An Evaluation of Serum Troponin T and Signal-averaged Electrocardiography in Predicting Electrocardiographic Abnormalities After Blunt Chest Trauma. J Trauma. 1997;43(2):304-10; discussion 310-2. PubMed PMID: 9291377.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - An evaluation of serum troponin T and signal-averaged electrocardiography in predicting electrocardiographic abnormalities after blunt chest trauma. AU - Fulda,G J, AU - Giberson,F, AU - Hailstone,D, AU - Law,A, AU - Stillabower,M, PY - 1997/8/1/pubmed PY - 1997/9/18/medline PY - 1997/8/1/entrez SP - 304-10; discussion 310-2 JF - The Journal of trauma JO - J Trauma VL - 43 IS - 2 N2 - OBJECTIVE: Despite multiple inquiries, there are no available tests to definitively detect blunt myocardial injury. The evaluation of patients with chest wall injuries without other indications for intensive care unit (ICU) admission has ranged from a single emergency department electrocardiogram (ECG) to 72 hours of continuous electrocardiographic monitoring. Recently, signal-averaged ECG and serum cardiac troponin T have demonstrated clinical utility in the evaluation of ischemic heart disease. The purpose of this study is to determine the ability of these diagnostic tests to predict the occurrence of significant electrocardiographic rhythm disturbances for patients with chest wall injuries and no other indication for ICU admission. METHODS: We prospectively evaluated 71 consecutive adult patients admitted to a regional Level I trauma center with chest wall injuries not requiring ICU admission. We obtained admission signal-averaged ECG, serum troponin T level, standard ECG, and creatine phosphokinase (CPK-MB) level. Patients received continuous electrocardiographic monitoring, follow-up 12-lead electrocardiography, and serial monitoring of troponin and CPK-MB. Echocardiography was performed for patients with abnormal CPK-MB levels. Electrocardiographic events were graded as normal, abnormal but clinically insignificant, or clinically significant. Multiple stepwise logistic regression analysis was used to evaluate predictors for the development of clinically significant electrocardiographic events. RESULTS: On admission, 17 of 71 patients (23.9%) had normal sinus rhythm; 13 (18.3%) had a clinically significant finding. For 50 patients, follow-up ECG was abnormal; for 26, the findings were clinically significant. Of 17 patients with normal initial ECGs, 7 (41%) developed a clinically significant abnormality. Six patients received intervention for ECG findings. Eleven of 71 patients (16%) had positive troponin T; 5 of 71 (7%) had positive CPK-MB; 15 of 71 (21%) had positive signal-averaged ECG; and 4 of 13 had positive echocardiograms. Initial electrocardiographic abnormalities and a troponin T level > 0.20 microg/L were the only variables found to predict clinically significant electrocardiographic events. Sensitivity and specificity of troponin T in predicting clinically significant abnormalities were 27 and 91%, respectively. CONCLUSIONS: 1. The best predictors for the development of significant electrocardiographic changes are an admission ECG abnormality and an elevated serum troponin T level. 2. Both tests have high specificity with low to moderate sensitivity. 3. Patients with normal ECGs may develop clinically significant events. 4. CPK-MB and echocardiograms continue to be poor predictors of significant electrocardiographic events. SN - 0022-5282 UR - https://www.unboundmedicine.com/medline/citation/9291377/An_evaluation_of_serum_troponin_T_and_signal_averaged_electrocardiography_in_predicting_electrocardiographic_abnormalities_after_blunt_chest_trauma_ L2 - https://doi.org/10.1097/00005373-199708000-00016 DB - PRIME DP - Unbound Medicine ER -