[MRI of the regions of the inner ear and cerebellopontine angle using a 3D T2-weighted turbo spin-echo sequence. Comparison with conventional 2D T2-weighted turbo spin-echo sequences and T1-weighted spin-echo sequences].
Rofo. 1997 Oct; 167(4):377-83.ROFO

Abstract

PURPOSE

To assess the value of a three-dimensional (3D) T2-weighted turbo spin-echo sequence (3D T2-TSE) in comparison to conventional two-dimensional (2D) T2-weighted TSE and unenhanced and enhanced T1-weighted spin-echo sequences (SE) in imaging anatomic structures and pathologic changes of the inner ear and cerebellopontine angle.

PATIENTS AND METHODS

The inner ear and cerebellopontine angle were investigated by MRI in three healthy volunteers and 18 patients performing a 2D T2-weighted turbo spin-echo sequence and a 3D T2-TSE in the axial plane. In the patient study, 2D T1-weighted SE sequences both before and after the i.v. injection of gadopentetate dimeglumine in both the axial and coronal plane were performed in addition.

RESULTS

Only the 3D T2-TSE enabled an accurate imaging of the anatomic structures. In cases of pathology, the 3D T2-TSE provided additional information to the performed 2D sequences. The combination of the 3D T2-TSE with unenhanced and enhanced 2D T1-weighted SE enabled the most accurate diagnosis in cases of pathology.

CONCLUSIONS

Accurate depiction of anatomic structures of the inner ear and cerebellopontine angle could be obtained by 3D T2-TSE only. The most accurate diagnosis in cases of pathology was provided by the combination of the 3D T2-TSE with unenhanced and enhanced 2D T1-weighted spin-echo sequences.

Authors+Show Affiliations

Abteilung für Osteologie/Universitätsklinik für Radiodiagnostik Wien.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Comparative Study
English Abstract
Journal Article

Language

ger

PubMed ID

9417266

Citation

Czerny, C, et al. "[MRI of the Regions of the Inner Ear and Cerebellopontine Angle Using a 3D T2-weighted Turbo Spin-echo Sequence. Comparison With Conventional 2D T2-weighted Turbo Spin-echo Sequences and T1-weighted Spin-echo Sequences]." RoFo : Fortschritte Auf Dem Gebiete Der Rontgenstrahlen Und Der Nuklearmedizin, vol. 167, no. 4, 1997, pp. 377-83.
Czerny C, Trattnig S, Baumgartner WD, et al. [MRI of the regions of the inner ear and cerebellopontine angle using a 3D T2-weighted turbo spin-echo sequence. Comparison with conventional 2D T2-weighted turbo spin-echo sequences and T1-weighted spin-echo sequences]. Rofo. 1997;167(4):377-83.
Czerny, C., Trattnig, S., Baumgartner, W. D., Gstöttner, W., & Imhof, H. (1997). [MRI of the regions of the inner ear and cerebellopontine angle using a 3D T2-weighted turbo spin-echo sequence. Comparison with conventional 2D T2-weighted turbo spin-echo sequences and T1-weighted spin-echo sequences]. RoFo : Fortschritte Auf Dem Gebiete Der Rontgenstrahlen Und Der Nuklearmedizin, 167(4), 377-83.
Czerny C, et al. [MRI of the Regions of the Inner Ear and Cerebellopontine Angle Using a 3D T2-weighted Turbo Spin-echo Sequence. Comparison With Conventional 2D T2-weighted Turbo Spin-echo Sequences and T1-weighted Spin-echo Sequences]. Rofo. 1997;167(4):377-83. PubMed PMID: 9417266.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - [MRI of the regions of the inner ear and cerebellopontine angle using a 3D T2-weighted turbo spin-echo sequence. Comparison with conventional 2D T2-weighted turbo spin-echo sequences and T1-weighted spin-echo sequences]. AU - Czerny,C, AU - Trattnig,S, AU - Baumgartner,W D, AU - Gstöttner,W, AU - Imhof,H, PY - 1998/1/7/pubmed PY - 1998/1/7/medline PY - 1998/1/7/entrez SP - 377 EP - 83 JF - RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin JO - Rofo VL - 167 IS - 4 N2 - PURPOSE: To assess the value of a three-dimensional (3D) T2-weighted turbo spin-echo sequence (3D T2-TSE) in comparison to conventional two-dimensional (2D) T2-weighted TSE and unenhanced and enhanced T1-weighted spin-echo sequences (SE) in imaging anatomic structures and pathologic changes of the inner ear and cerebellopontine angle. PATIENTS AND METHODS: The inner ear and cerebellopontine angle were investigated by MRI in three healthy volunteers and 18 patients performing a 2D T2-weighted turbo spin-echo sequence and a 3D T2-TSE in the axial plane. In the patient study, 2D T1-weighted SE sequences both before and after the i.v. injection of gadopentetate dimeglumine in both the axial and coronal plane were performed in addition. RESULTS: Only the 3D T2-TSE enabled an accurate imaging of the anatomic structures. In cases of pathology, the 3D T2-TSE provided additional information to the performed 2D sequences. The combination of the 3D T2-TSE with unenhanced and enhanced 2D T1-weighted SE enabled the most accurate diagnosis in cases of pathology. CONCLUSIONS: Accurate depiction of anatomic structures of the inner ear and cerebellopontine angle could be obtained by 3D T2-TSE only. The most accurate diagnosis in cases of pathology was provided by the combination of the 3D T2-TSE with unenhanced and enhanced 2D T1-weighted spin-echo sequences. SN - 1438-9029 UR - https://www.unboundmedicine.com/medline/citation/9417266/[MRI_of_the_regions_of_the_inner_ear_and_cerebellopontine_angle_using_a_3D_T2_weighted_turbo_spin_echo_sequence__Comparison_with_conventional_2D_T2_weighted_turbo_spin_echo_sequences_and_T1_weighted_spin_echo_sequences]_ L2 - http://www.thieme-connect.com/DOI/DOI?10.1055/s-2007-1015547 DB - PRIME DP - Unbound Medicine ER -