Tags

Type your tag names separated by a space and hit enter

Isotope dilution-liquid chromatography/electrospray ionization-tandem mass spectrometry for the determination of serum thyroxine as a potential reference method.
Rapid Commun Mass Spectrom. 1998; 12(16):1099-103.RC

Abstract

A new candidate reference method is presented for the determination of thyroxine in serum. The method is based on isotope dilution-liquid chromatography/tandem mass spectrometry using electrospray for ionization. The internal standard used was 13C6-thyroxine, sample pretreatment consisted of protein precipitation and a two-step liquid/liquid extraction procedure, HPLC was performed on a C-18 column with an eluent containing methanol/water/formic acid (60:40:0.1, by volume), and finally thyroxine and its isotopically labeled analogue were measured in the selected reaction monitoring mode for the transitions m/z 777.7--> 731.7 and m/z 783.7--> 737.7, respectively. The detection limit for thyroxine was 6 pg, the within-run coefficient of variation was 1.1%. The samples were measured in six-fold: in duplicate on three independent days. The mean overall coefficient of variation of the method was 1.6%. The new method was evaluated by measuring nine control sera previously determined by an existing ID-GC/MS method. The differences between the results of the two methods ranged from-1.6% to +3.3%, with a mean of +0.2%.

Authors+Show Affiliations

Laboratoria voor Medische Biochemie en Klinische Analyse, Faculty of Pharmaceutical Sciences, University of Ghent, Belgium.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

9737016

Citation

De Brabandere, V I., et al. "Isotope Dilution-liquid Chromatography/electrospray Ionization-tandem Mass Spectrometry for the Determination of Serum Thyroxine as a Potential Reference Method." Rapid Communications in Mass Spectrometry : RCM, vol. 12, no. 16, 1998, pp. 1099-103.
De Brabandere VI, Hou P, Stöckl D, et al. Isotope dilution-liquid chromatography/electrospray ionization-tandem mass spectrometry for the determination of serum thyroxine as a potential reference method. Rapid Commun Mass Spectrom. 1998;12(16):1099-103.
De Brabandere, V. I., Hou, P., Stöckl, D., Thienpont, L. M., & De Leenheer, A. P. (1998). Isotope dilution-liquid chromatography/electrospray ionization-tandem mass spectrometry for the determination of serum thyroxine as a potential reference method. Rapid Communications in Mass Spectrometry : RCM, 12(16), 1099-103.
De Brabandere VI, et al. Isotope Dilution-liquid Chromatography/electrospray Ionization-tandem Mass Spectrometry for the Determination of Serum Thyroxine as a Potential Reference Method. Rapid Commun Mass Spectrom. 1998;12(16):1099-103. PubMed PMID: 9737016.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Isotope dilution-liquid chromatography/electrospray ionization-tandem mass spectrometry for the determination of serum thyroxine as a potential reference method. AU - De Brabandere,V I, AU - Hou,P, AU - Stöckl,D, AU - Thienpont,L M, AU - De Leenheer,A P, PY - 1998/9/16/pubmed PY - 2000/6/20/medline PY - 1998/9/16/entrez SP - 1099 EP - 103 JF - Rapid communications in mass spectrometry : RCM JO - Rapid Commun Mass Spectrom VL - 12 IS - 16 N2 - A new candidate reference method is presented for the determination of thyroxine in serum. The method is based on isotope dilution-liquid chromatography/tandem mass spectrometry using electrospray for ionization. The internal standard used was 13C6-thyroxine, sample pretreatment consisted of protein precipitation and a two-step liquid/liquid extraction procedure, HPLC was performed on a C-18 column with an eluent containing methanol/water/formic acid (60:40:0.1, by volume), and finally thyroxine and its isotopically labeled analogue were measured in the selected reaction monitoring mode for the transitions m/z 777.7--> 731.7 and m/z 783.7--> 737.7, respectively. The detection limit for thyroxine was 6 pg, the within-run coefficient of variation was 1.1%. The samples were measured in six-fold: in duplicate on three independent days. The mean overall coefficient of variation of the method was 1.6%. The new method was evaluated by measuring nine control sera previously determined by an existing ID-GC/MS method. The differences between the results of the two methods ranged from-1.6% to +3.3%, with a mean of +0.2%. SN - 0951-4198 UR - https://www.unboundmedicine.com/medline/citation/9737016/Isotope_dilution_liquid_chromatography/electrospray_ionization_tandem_mass_spectrometry_for_the_determination_of_serum_thyroxine_as_a_potential_reference_method_ DB - PRIME DP - Unbound Medicine ER -