Tags

Type your tag names separated by a space and hit enter

Simultaneous determination of pseudoephidrine HCl (PSE) and terfanidine (TER) from formulations by reversed-phase ion pair high-performance liquid chromatography (RP-HPLC).
Drug Dev Ind Pharm. 1998 Mar; 24(3):219-23.DD

Abstract

A new simple, precise, rapid, and selective reversed-phase ion pair high-performance liquid chromatography (RP-HPLC) method has been developed for the simultaneous determination of pseudoephidrine (PSE) and terfanidine (TER) from tablets using 60:15:25 acetontrile:methanol:water (v/v) containing 2.9 g sodium lauryl sulfate/liter, pH adjusted to 3.1 using phosphoric acid as a mobile phase and C18 Spherisorb ODS 2 (3 microns, 5 cm x 4.6 mm i.d.) as stationary phase. Detection was carried out using a UV detector at 254 nm. A constant flow of 1.0 ml/min was maintained throughout the analysis. Retention times for PSE and TER were 1.90 and 7.35 min, respectively. Linearity range and percentage recoveries for PSE and TER were 24-1200 and 12-600 micrograms/ml, and 100.01 and 100.4%, respectively.

Authors+Show Affiliations

Department of Chemistry, Institute of Science, Mumbai, India.No affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

9876578

Citation

Argekar, A P., et al. "Simultaneous Determination of Pseudoephidrine HCl (PSE) and Terfanidine (TER) From Formulations By Reversed-phase Ion Pair High-performance Liquid Chromatography (RP-HPLC)." Drug Development and Industrial Pharmacy, vol. 24, no. 3, 1998, pp. 219-23.
Argekar AP, Shah SJ, Raj SV. Simultaneous determination of pseudoephidrine HCl (PSE) and terfanidine (TER) from formulations by reversed-phase ion pair high-performance liquid chromatography (RP-HPLC). Drug Dev Ind Pharm. 1998;24(3):219-23.
Argekar, A. P., Shah, S. J., & Raj, S. V. (1998). Simultaneous determination of pseudoephidrine HCl (PSE) and terfanidine (TER) from formulations by reversed-phase ion pair high-performance liquid chromatography (RP-HPLC). Drug Development and Industrial Pharmacy, 24(3), 219-23.
Argekar AP, Shah SJ, Raj SV. Simultaneous Determination of Pseudoephidrine HCl (PSE) and Terfanidine (TER) From Formulations By Reversed-phase Ion Pair High-performance Liquid Chromatography (RP-HPLC). Drug Dev Ind Pharm. 1998;24(3):219-23. PubMed PMID: 9876578.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Simultaneous determination of pseudoephidrine HCl (PSE) and terfanidine (TER) from formulations by reversed-phase ion pair high-performance liquid chromatography (RP-HPLC). AU - Argekar,A P, AU - Shah,S J, AU - Raj,S V, PY - 1999/1/7/pubmed PY - 1999/1/7/medline PY - 1999/1/7/entrez SP - 219 EP - 23 JF - Drug development and industrial pharmacy JO - Drug Dev Ind Pharm VL - 24 IS - 3 N2 - A new simple, precise, rapid, and selective reversed-phase ion pair high-performance liquid chromatography (RP-HPLC) method has been developed for the simultaneous determination of pseudoephidrine (PSE) and terfanidine (TER) from tablets using 60:15:25 acetontrile:methanol:water (v/v) containing 2.9 g sodium lauryl sulfate/liter, pH adjusted to 3.1 using phosphoric acid as a mobile phase and C18 Spherisorb ODS 2 (3 microns, 5 cm x 4.6 mm i.d.) as stationary phase. Detection was carried out using a UV detector at 254 nm. A constant flow of 1.0 ml/min was maintained throughout the analysis. Retention times for PSE and TER were 1.90 and 7.35 min, respectively. Linearity range and percentage recoveries for PSE and TER were 24-1200 and 12-600 micrograms/ml, and 100.01 and 100.4%, respectively. SN - 0363-9045 UR - https://www.unboundmedicine.com/medline/citation/9876578/Simultaneous_determination_of_pseudoephidrine_HCl__PSE__and_terfanidine__TER__from_formulations_by_reversed_phase_ion_pair_high_performance_liquid_chromatography__RP_HPLC__ L2 - https://www.tandfonline.com/doi/full/10.3109/03639049809085613 DB - PRIME DP - Unbound Medicine ER -