[Data processing system for laboratory and hemodynamic heart catheterization measurements].
Z Kardiol. 1976 Oct; 65(10):850-81.ZK

Abstract

In cooperation with the Department of Electronic Data Processing Systems we have developed a data processing unit for the analysis of hemodynamic data at the Department of Internal Medicine I. The aim was to design a computer-system for the daily routine in heart-catheterizations as well as for the solution of scientific problems during hemodynamic studies. In the on-line-mode besides the ECG up to four pressures can be analysed simultaneously. Analog and digital tapes can also be processed off-line on demand. The concept of the whole system and the individual steps of computer-handling are adjusted to the problems of data-analysis in praxis from the viewpoint of the examining cardiologist. Since the system is interactive after each measurement and each given command the computer-results are displayed on the video-scope. Because of the modular structure of the program new medical criteria can easily be implemented at any time. Since the computer-system is not effectively used with only one cath-lab other units possibly of different hard-ware configuration can be connected simultaneously to the computer. Each cath-lab shares 16 K out of the total 32 K core-memory. The results are displayed graphically and alpha-numerically on video-scope, x-y-plotter and line printer. The sampling-rate for fluid-filled catheters is 200 Hz and for catheter-tip-manometers 400 Hz. Smothing and differentiation-procedures are adapted to the respective catheter-material. The computer-program calibrates the different pressure amplifiers automatically. After defining the catheter-position the pressure-signals are sampled for 10 s and immediately afterwards analyzed by the computer. The ECG and the corresponding pressure-curves are displayed on the video-scope. The automatically selected representative beat as well as each of the identified and numerated other beats of the sampling-phase can be displayed selectively together with its numerical results. The computer marks the positions within the pressure-curves, where the individual measurements were taken. Besides the systolic and diastolic pressures in valvular stenosis the maximal and mean systolic or diastolic gradients, ejection- or filling-period, valve-flow and valve-area are calculated autonomously. The calculation of cardiac-output, different volume-indices and stroke-work-index are based on Fick-method, thermo- or indicator-dilution technique. The contractility-parameters max dp/dt, t-max dp/dt, max dp/dt/DP, max dp/dt/P, VPM, V40, min dp/dt and the stiffness are computed for the left and on demand also for the right ventricle. Data of the patient and the operating-team, catheter-technique, complications and free comments are transmitted to the computer via terminal together with the actual time. The computer-system was drafted for permanent use. Therefore possible technical defects have been anticipated in the design of hard- and soft-ware. In cases of failure suitable steps allow the immediate restart of the system without loosing information...

Authors

No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

English Abstract
Journal Article

Language

ger

PubMed ID

997705

Citation

Jensch, P, et al. "[Data Processing System for Laboratory and Hemodynamic Heart Catheterization Measurements]." Zeitschrift Fur Kardiologie, vol. 65, no. 10, 1976, pp. 850-81.
Jensch P, Meyer J, Mattar E, et al. [Data processing system for laboratory and hemodynamic heart catheterization measurements]. Z Kardiol. 1976;65(10):850-81.
Jensch, P., Meyer, J., Mattar, E., Ameling, W., & Effert, S. (1976). [Data processing system for laboratory and hemodynamic heart catheterization measurements]. Zeitschrift Fur Kardiologie, 65(10), 850-81.
Jensch P, et al. [Data Processing System for Laboratory and Hemodynamic Heart Catheterization Measurements]. Z Kardiol. 1976;65(10):850-81. PubMed PMID: 997705.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - [Data processing system for laboratory and hemodynamic heart catheterization measurements]. AU - Jensch,P, AU - Meyer,J, AU - Mattar,E, AU - Ameling,W, AU - Effert,S, PY - 1976/10/1/pubmed PY - 1976/10/1/medline PY - 1976/10/1/entrez SP - 850 EP - 81 JF - Zeitschrift fur Kardiologie JO - Z Kardiol VL - 65 IS - 10 N2 - In cooperation with the Department of Electronic Data Processing Systems we have developed a data processing unit for the analysis of hemodynamic data at the Department of Internal Medicine I. The aim was to design a computer-system for the daily routine in heart-catheterizations as well as for the solution of scientific problems during hemodynamic studies. In the on-line-mode besides the ECG up to four pressures can be analysed simultaneously. Analog and digital tapes can also be processed off-line on demand. The concept of the whole system and the individual steps of computer-handling are adjusted to the problems of data-analysis in praxis from the viewpoint of the examining cardiologist. Since the system is interactive after each measurement and each given command the computer-results are displayed on the video-scope. Because of the modular structure of the program new medical criteria can easily be implemented at any time. Since the computer-system is not effectively used with only one cath-lab other units possibly of different hard-ware configuration can be connected simultaneously to the computer. Each cath-lab shares 16 K out of the total 32 K core-memory. The results are displayed graphically and alpha-numerically on video-scope, x-y-plotter and line printer. The sampling-rate for fluid-filled catheters is 200 Hz and for catheter-tip-manometers 400 Hz. Smothing and differentiation-procedures are adapted to the respective catheter-material. The computer-program calibrates the different pressure amplifiers automatically. After defining the catheter-position the pressure-signals are sampled for 10 s and immediately afterwards analyzed by the computer. The ECG and the corresponding pressure-curves are displayed on the video-scope. The automatically selected representative beat as well as each of the identified and numerated other beats of the sampling-phase can be displayed selectively together with its numerical results. The computer marks the positions within the pressure-curves, where the individual measurements were taken. Besides the systolic and diastolic pressures in valvular stenosis the maximal and mean systolic or diastolic gradients, ejection- or filling-period, valve-flow and valve-area are calculated autonomously. The calculation of cardiac-output, different volume-indices and stroke-work-index are based on Fick-method, thermo- or indicator-dilution technique. The contractility-parameters max dp/dt, t-max dp/dt, max dp/dt/DP, max dp/dt/P, VPM, V40, min dp/dt and the stiffness are computed for the left and on demand also for the right ventricle. Data of the patient and the operating-team, catheter-technique, complications and free comments are transmitted to the computer via terminal together with the actual time. The computer-system was drafted for permanent use. Therefore possible technical defects have been anticipated in the design of hard- and soft-ware. In cases of failure suitable steps allow the immediate restart of the system without loosing information... SN - 0300-5860 UR - https://www.unboundmedicine.com/medline/citation/997705/[Data_processing_system_for_laboratory_and_hemodynamic_heart_catheterization_measurements]_ DB - PRIME DP - Unbound Medicine ER -