Bioelectric impedance predicts total body water, blood pressure, and heart rate during hemodialysis in children and adolescents.
J Ren Nutr. 2008 May; 18(3):304-11.JR

Abstract

OBJECTIVE

The purposes of our study were to: (1) assess if changes in the volemic status of children and adolescents over the course of standard dialysis could be observed using bioelectric impedance (BIA); and (2) evaluate whether the variability of blood pressure (systolic blood pressure, SBP; diastolic blood pressure, DBP) and heart rate (HR) could be explained by independent variables from BIA data.

DESIGN

We used a randomized, single-blinded treatment and repeated-measures design.

SETTING

This study took place at the DaVita Children's Dialysis Center (Chicago, IL).

PATIENTS

There were 7 subjects, aged 10 to 16 years.

INTERVENTION

Two identical standard hemodialysis (HD) sessions were completed, with data collected five times during each HD session: pre-HD, intra-HD (hours 1, 2, and 3), and post-HD. Endpoints included total body water (TBW), resistance (R), reactance (Xc), bioimpedance vector |Z|, supine and sitting SBP, DBP, and HR. Standing SBP, DBP, and HR were collected pre-HD and post-HD.

RESULTS

No differences were observed in TBW between HD sessions for all subjects. However, TBW decreased throughout the HD sessions for all subjects (although no significant differences were seen between hour 3 and post-HD). Reactance (representative of extracellular water) correlated with supine, sitting, and standing SBP (r = 0.55, 0.59, and 0.51, respectively; P < or = .008). The bioimpedance vector increased beginning at hour 1 (P < .001), reflective of a decline in tissue hydration over the course of HD.

CONCLUSIONS

Weight gain in end-stage kidney disease patients is largely fluid. Thus, the use of BIA during HD may aid in the prediction of cardiovascular instability before the development of symptoms, because intravascular hypovolemia and hypotension can result from excessive ultrafiltration below the critical dry weight. In addition, BIA explains, in part, the variability of SBP, DBP, and HR during HD. We suggest that our data also demonstrates the delay in mobilization of fluid from the interstitial space for plasma refill, as evidenced by the delayed change in |Z| over HD. Bioelectric impedance is useful for explaining changes in volemic status and, in part, the variability of SBP, DBP, and HR during HD.

Links

Publisher Full Text
Aggregator Full Text

Authors+Show Affiliations

Brooks ER
Department of Pediatrics, Division of Kidney Diseases, Northwestern University Feinberg Medical School, Children's Memorial Hospital, Chicago, Illinois 60614, USA. e-brooks3@northwestern.edu
Fatallah-Shaykh SA
No affiliation info available
Langman CB
No affiliation info available
Wolf KM
No affiliation info available
Price HE
No affiliation info available

MeSH

AdolescentBlood PressureBody CompositionBody WaterChildElectric ImpedanceFemaleHeart RateHumansKidney Failure, ChronicMalePredictive Value of TestsRenal DialysisSingle-Blind Method

Pub Type(s)

Journal Article
Randomized Controlled Trial
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

18410888